Climate test chamber temp. -70 to 180°CWeiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Climate test chamber temp. -70 to 180°C
Weiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
وضعیت
کارکرده
موقعیت
Borken 

اطلاعات دستگاه
- نام دستگاه:
- Climate test chamber temp. -70 to 180°C
- تولید کننده:
- Weiss explosionsgeschützt
- وضعیت:
- بسیار خوب (کارکرده)
قیمت و مکان
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A22241172
- شماره مرجع:
- 20744
- بهروزرسانی:
- آخرین بهروزرسانی در ۱۰.۰۴.۱۴۰۵
توضیحات
Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
Prsdpfxjzh D Ryo Agrja
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
Prsdpfxjzh D Ryo Agrja
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
ارسال درخواست
تلفن & فکس
+49 2861 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
آگهی کوچک
Wiefelstede
۴٬۲۸۰ km
GEDORETORCOFIX -Z 80-400 Nm
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است