Temperature test chamber 335 litersVötsch
VTS 7034-5 -70°C bis +180°C
Temperature test chamber 335 liters
Vötsch
VTS 7034-5 -70°C bis +180°C
وضعیت
کارکرده
موقعیت
Borken 

تصاویر نشان میدهند
نمایش نقشه
اطلاعات دستگاه
قیمت و مکان
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A7823351
- شماره مرجع:
- 23261
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۵.۰۸.۱۴۰۳
توضیحات
Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
Dcodpfx Ageir D U Dj Ijr
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6,5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free field measurement) < 69dB (A)
side entry 5,5 cm / 12,5 cm
cabinet is water cooled
Refrigerant: R 452A and R 23
weight approx. 570 kg
Type: VTS 7034-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
Dcodpfx Ageir D U Dj Ijr
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
تأمینکننده
توجه: به صورت رایگان ثبتنام کنید یا وارد شوید, تا به تمام اطلاعات دسترسی داشته باشید.
ثبت شده از: 2012
ارسال درخواست
تلفن & فکس
+49 2861 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
آگهی کوچک
Borken
۴٬۳۲۷ km
Vötsch-70°C bis +180°C VTS 7034-5
آگهی کوچک
Roreto
۴٬۱۵۷ km
WEMHONERVARIOPRESS Basic + (KT-MB-28/15-240)
آگهی کوچک
Borken
۴٬۳۲۷ km
Vötsch-70°C bis +180°C VTS 7034-5
آگهی کوچک
Chemnitz
۳٬۸۹۲ km
MitutoyoContracer CV-2100M4
آگهی کوچک
Borken
۴٬۳۲۷ km
ZeissDSM 962
آگهی کوچک
Scerne
۳٬۶۴۳ km
OrmamacchineLS/L/R 30 13
آگهی کوچک
Wien
۳٬۵۷۵ km
BOY
آگهی کوچک
Umraniye
۲٬۳۸۳ km
BOSPORASACOUSTIC SOUND BARRIER PANEL
آگهی کوچک
Velžys
۳٬۴۴۰ km
TRIULZI-IGTilting table
آگهی کوچک
ایتالیا
۳٬۷۵۸ km
SCHELLINGFH6 430
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است