CTS climate test chamber CW-60/5.5, -60°C to +100°C, 5,500 liters (5.5 m³)CTS
Klimakammer CW -60/5,5
CTS climate test chamber CW-60/5.5, -60°C to +100°C, 5,500 liters (5.5 m³)
CTS
Klimakammer CW -60/5,5
وضعیت
کارکرده
موقعیت
Borken 

اطلاعات پایه
- تولید کننده:
- CTS
- وضعیت:
- کارکرده
قیمت و مکان
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A22271307
- شماره مرجع:
- 24907
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۳.۰۷.۱۴۰۵
توضیحات
CTS
CTS CW‑60/5.5 – Water-Cooled Climatic Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climatic chamber for performing temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climatic test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The efficient air circulation with a correspondingly high air exchange rate guarantees
good heat transfer to the test specimen.
The air handling unit is located on the rear of the interior chamber.
The components are located in a separate frame behind the device and are easily accessible.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air using a fan.
Technical Performance Data:
Temperature Tests:
Temperature range: -60 °C to +100 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate: linear, depending on the test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
Temperature range: +10 °C to +90 °C
Humidity range: 10 % to 95 % relative humidity
in the dew point range: +5 °C to +89 °C
Temperature deviation: ± 0.5 K over time
Humidity deviation: ±1 to ±3 % RH over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class: IP 54
Technical Design:
Refrigeration unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See image)
Ibedozizmnjpfx Amtoc
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
CTS CW‑60/5.5 – Water-Cooled Climatic Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized,
walk-in or drive-in climatic chamber for performing temperature
and humidity tests on multiple test specimens simultaneously.
Device Description
The climatic test chamber can be used to test the function or material properties of a test specimen
under temperature and humidity conditions.
The efficient air circulation with a correspondingly high air exchange rate guarantees
good heat transfer to the test specimen.
The air handling unit is located on the rear of the interior chamber.
The components are located in a separate frame behind the device and are easily accessible.
The control system is housed in a separate control cabinet.
The operating panel is integrated into the control cabinet door.
To dehumidify the test chamber, the chamber is equipped with a self-regenerating compressed air dryer.
The test chamber can be purged with fresh air using a fan.
Technical Performance Data:
Temperature Tests:
Temperature range: -60 °C to +100 °C
Temperature deviation: ±0.5 to 1 K over time
Temperature change rate: linear, depending on the test specimen
and with heat radiation, measured in the supply air
Heating: 2 K/min from -40 °C to +85 °C
Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
Temperature range: +10 °C to +90 °C
Humidity range: 10 % to 95 % relative humidity
in the dew point range: +5 °C to +89 °C
Temperature deviation: ± 0.5 K over time
Humidity deviation: ±1 to ±3 % RH over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable space):
Volume: approx. 5,500 liters (5.5 m³)
Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
Rated power: 58.3 kW (incl. 5 sockets)
Rated current: 86.0 A
Protection class: IP 54
Technical Design:
Refrigeration unit:
water-cooled, low noise, semi-hermetic,
stepless power adjustment through electronic
monitoring and control system,
environmentally friendly refrigerant R 23 / R 404 A
Notes
Inspection possible by appointment (46325 Borken)
Shipping by freight forwarder possible – costs & organization on request
Scope of supply: (See image)
Ibedozizmnjpfx Amtoc
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.