Climatic chamber with humidity, -70°C to 180°CWeiss
WK11-600/70/5
Climatic chamber with humidity, -70°C to 180°C
Weiss
WK11-600/70/5
وضعیت
کارکرده
موقعیت
Borken 

تصاویر نشان میدهند
نمایش نقشه
اطلاعات دستگاه
قیمت و مکان
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A21144637
- شماره مرجع:
- 25022
- بهروزرسانی:
- آخرین بهروزرسانی در ۱۳.۱۱.۱۴۰۴
توضیحات
Weiss
Type: WK11 - 600/70/5
Weiss Climate Chamber Water-Cooled
The Weiss climate chamber WK11-600/70/5 with approximately 600 liters usable volume is suitable for temperature and humidity testing, as well as for the conditioning of samples and materials in a range from −70 °C to +180 °C.
Simcon/32 - Net controller
Technical Data:
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Temperature Test Data:
Temperature range: -70 °C to +180°C
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviations: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
At +20 °C: 5000 W
At -20 °C: 5000 W
Climate Test Data:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r. H.
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.3 K
Spatial temperature deviations: ±0.5 to ±1 K
Temperature gradient: 1 to 2
Humidity fluctuation (temporal, center of usable space): ±1 to ±3% r. H.
Heat compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Main fuse (to be provided by customer): 32 A slow-blow
Permissible test material weight:
Total load of racks: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 675 kg
Refrigerants: R452A / R23
Blsdpfx Aoyglb Ssbvjc
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information:
The following points are completed on our offered chambers beforehand:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical specifications subject to change and errors excepted!)
We are happy to answer any further questions over the phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Type: WK11 - 600/70/5
Weiss Climate Chamber Water-Cooled
The Weiss climate chamber WK11-600/70/5 with approximately 600 liters usable volume is suitable for temperature and humidity testing, as well as for the conditioning of samples and materials in a range from −70 °C to +180 °C.
Simcon/32 - Net controller
Technical Data:
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Temperature Test Data:
Temperature range: -70 °C to +180°C
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviations: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
At +20 °C: 5000 W
At -20 °C: 5000 W
Climate Test Data:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r. H.
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.3 K
Spatial temperature deviations: ±0.5 to ±1 K
Temperature gradient: 1 to 2
Humidity fluctuation (temporal, center of usable space): ±1 to ±3% r. H.
Heat compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Main fuse (to be provided by customer): 32 A slow-blow
Permissible test material weight:
Total load of racks: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 675 kg
Refrigerants: R452A / R23
Blsdpfx Aoyglb Ssbvjc
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information:
The following points are completed on our offered chambers beforehand:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical specifications subject to change and errors excepted!)
We are happy to answer any further questions over the phone.