Weiss Climate Chamber WK-600/70 (I)-(II) 2 G EEx Temp. -70 to 180°C (explosion-proof)Weiss
WK-600/70
Weiss Climate Chamber WK-600/70 (I)-(II) 2 G EEx Temp. -70 to 180°C (explosion-proof)
Weiss
WK-600/70
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۲۱٬۰۰۰
وضعیت
کارکرده
موقعیت
Borken 

قیمت و مکان
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۲۱٬۰۰۰
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A22241172
- شماره مرجع:
- 20744
- بهروزرسانی:
- آخرین بهروزرسانی در ۰۸.۰۸.۱۴۰۵
توضیحات
Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
Todpfx Abezh D Rysned
External dimensions with hinges and door closure
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door closure
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold / Heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98 % RH
Temperature change per unit of time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse, customer-supplied: 32 A slow-blow
Permissible test item weight
Total load of the grid supports 80 kg
Test chamber floor 80 kg, insert grid 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, here is the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
Todpfx Abezh D Rysned
External dimensions with hinges and door closure
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door closure
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold / Heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98 % RH
Temperature change per unit of time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse, customer-supplied: 32 A slow-blow
Permissible test item weight
Total load of the grid supports 80 kg
Test chamber floor 80 kg, insert grid 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, here is the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
ارسال درخواست
تلفن & فکس
+49 2861 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۲۷ km
WeissWK11-600/70 EX ATEX
موفق
پیام شما ارسال شد.
آگهی کوچک
Wiefelstede
۴٬۲۸۰ km
GEDORETORCOFIX -Z 80-400 Nm
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۲۷ km
WeissWK11-600/70/5
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است