Weiss
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature-controlled shock testing chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to installation plan: 700 / 500 mm
Installation dimensions according to installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Hedpfxjz Rwk Rs Abnew
Temperature deviation over time: ±0.3 to ±0.5 K in steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load, test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7 pieces
Maximum load per insert basket: 7.5 kg
Maximum total load of insert baskets: 50 kg
Distance between insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone, or tablet
Interfaces: Ethernet, USB, and digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to nameplate
Other connection options according to instructions: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class, control cabinet and operating unit: IP23
Cooling: water-cooled
Cooling water connections: Supply and return, each 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure, cooling water circuit: over 2 bar
Cooling water consumption under full load with 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load with 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation location: max. 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or freight transport possible.
Subject to changes, errors, and prior sale.
We will be happy to answer any further questions by telephone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Weiss ShockEvent D/210/a/V1
Type of equipment: Temperature-controlled shock testing chamber
Testing principle: Stationary test chamber with supply of warm, cold, and ambient air via flaps
Test chamber volume: approx. 210 liters
Usable test chamber width / height according to installation plan: 700 / 500 mm
Installation dimensions according to installation plan (W × D × H): approx. 1,480 × 1,670 × 1,967 mm, plus space for attachments
Weight: approx. 1,350 kg
Temperature range, warm chamber: +50 to +225 °C
Temperature range, test chamber, warm phase: +50 to +200 °C
Temperature range, test chamber, cold phase: −65 to 0 °C
Temperature range, cold chamber: −70 to 0 °C
Heating rate: 18 K/min, i.e. 18 °C
Cooling rate: 2 K/min, i.e. 2 °C
Hedpfxjz Rwk Rs Abnew
Temperature deviation over time: ±0.3 to ±0.5 K in steady state
Temperature homogeneity spatially: ±0.5 to ±1.5 K
Heat compensation, cold phase: max. 6,000 W at −20 °C
Heat compensation, warm phase: 0 W
Maximum load, test chamber floor: 100 kg, evenly distributed
Maximum number of insert baskets: 7 pieces
Maximum load per insert basket: 7.5 kg
Maximum total load of insert baskets: 50 kg
Distance between insert baskets: 50 mm
Operation: WEBPanel touch display with WEBSeason®
Remote control: via computer, smartphone, or tablet
Interfaces: Ethernet, USB, and digital I/O
Power connection: 3/N/PE AC 400 V ±10 %, 50 Hz; actual design according to nameplate
Other connection options according to instructions: 380 V / 50 Hz or optionally 440 V / 60 Hz
Rated power: 31.9 kW
Rated current: 57 A
On-site protection: 63 A slow-blow fuse
Protection class, control cabinet and operating unit: IP23
Cooling: water-cooled
Cooling water connections: Supply and return, each 1" internal thread
Cooling water temperature: +12 to +28 °C
Cooling water pressure: 2.5 to 6 bar
Differential pressure, cooling water circuit: over 2 bar
Cooling water consumption under full load with 18 °C inlet and 10 K heating: 2.9 m³/h
Cooling water consumption under full load with 28 °C inlet and 5 K heating: 5.8 m³/h
Maximum heat dissipation to the cooling water: 33.7 kW
Maximum heat dissipation to the installation room: 1 kW
Compressed air supply: 4 to 10 bar overpressure
Compressed air connection: quick-release coupling DN 7.2
Compressed air temperature: +2 to +50 °C
Condensate drain: hose connection Ø 8 mm
Sound pressure level: approx. 63 dB(A)
Permissible ambient temperature during operation: +10 to +35 °C
Permissible relative humidity at the installation location: max. 75 %
Refrigerant:
R449A 3.5 kg
R469A 2.5 kg
Shipping or freight transport possible.
Subject to changes, errors, and prior sale.
We will be happy to answer any further questions by telephone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
ارسال درخواست
تلفن & فکس
+49 2861 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
موفق
پیام شما ارسال شد.
آگهی کوچک
Freising
۳٬۹۱۰ km
JEOLJCM-7000
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است