Pulse generator for insulation testGBS Elektronik
rev3 Isolationstests bis 6nF
Pulse generator for insulation test
GBS Elektronik
rev3 Isolationstests bis 6nF
VB به اضافه مالیات بر ارزش افزوده
€۳٬۷۸۰
وضعیت
کارکرده
موقعیت
Borken 

تصاویر نشان میدهند
نمایش نقشه
اطلاعات دستگاه
- نام دستگاه:
- Pulse generator for insulation test
- تولید کننده:
- GBS Elektronik
- وضعیت:
- تقریباً نو (استفادهشده)
قیمت و مکان
VB به اضافه مالیات بر ارزش افزوده
€۳٬۷۸۰
- موقعیت:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A17569468
- شماره مرجع:
- 21007
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۴.۱۱.۱۴۰۴
توضیحات
GBS Test Pulse Rev. 3 Pulse Generator for Long-Term Insulation Tests
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Ksdpfx Agju Egz Rsbjlp
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Ksdpfx Agju Egz Rsbjlp
تأمینکننده
توجه: به صورت رایگان ثبتنام کنید یا وارد شوید, تا به تمام اطلاعات دسترسی داشته باشید.
آخرین بار آنلاین: هفته گذشته
ثبت شده از: 2008
۵۹۳ آگهیهای آنلاین
ارسال درخواست
تلفن & فکس
+49 2862 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
آگهی کوچک
Soerendonk
۴٬۴۰۴ km
Flender / SiemensK2S-2,5
آگهی کوچک
Wiefelstede
۴٬۲۸۰ km
Heuer FrontSpannweite 235 mm
آگهی کوچک
آلمان
۴٬۰۶۹ km
Kalchschmid3076
آگهی کوچک
Tönisvorst
۴٬۳۴۳ km
mitlaufendSPH 150 mm
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است