CTS climate chamber CW-40/16 -40°C to +140°CCTS
Klimaprüfzelle CW-40/16
CTS climate chamber CW-40/16 -40°C to +140°C
CTS
Klimaprüfzelle CW-40/16
وضعیت
کارکرده
موقعیت
Borken 

اطلاعات پایه
قیمت و مکان
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A22147807
- شماره مرجع:
- 23182
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۳.۰۷.۱۴۰۵
توضیحات
CTS
Type: CW-40/16
CTS Climate Chamber, Climate Test Cell, Water-Cooled
Height-adjustable!
Footprint approx. (W x D x H): 3755 x 3470 x 2480
Test chamber approx. (W x D x H): 2500 x 2720 x 2200
Test chamber volume: 14960 liters
Temperature range: -40°C to +140°C
Temperature deviation: 1 K over time
Average temperature change rate
without heat radiation, measured in the supply air
Heating: 2 K/min
Cooling: 1 K/min
Ijdpfx Aozd R A Usnkjtn
from +110°C to -35°C
Climate tests:
Temperature range: +10°C to +90°C
Humidity range: +30% to +95% RH
in the dew point range: +5°C to 89°C
Temperature deviation: 0.5 K over time
Humidity deviation: ±1 to ±3% RH over time
Rated voltage: 400V 3/N, PE, 50 Hz
Rated power: 53.5 kW
Rated current: 92.3 A
Compressor: S6J-16.2
+ Chilled water unit
Refrigerant: R404A
Weight: 5500 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Type: CW-40/16
CTS Climate Chamber, Climate Test Cell, Water-Cooled
Height-adjustable!
Footprint approx. (W x D x H): 3755 x 3470 x 2480
Test chamber approx. (W x D x H): 2500 x 2720 x 2200
Test chamber volume: 14960 liters
Temperature range: -40°C to +140°C
Temperature deviation: 1 K over time
Average temperature change rate
without heat radiation, measured in the supply air
Heating: 2 K/min
Cooling: 1 K/min
Ijdpfx Aozd R A Usnkjtn
from +110°C to -35°C
Climate tests:
Temperature range: +10°C to +90°C
Humidity range: +30% to +95% RH
in the dew point range: +5°C to 89°C
Temperature deviation: 0.5 K over time
Humidity deviation: ±1 to ±3% RH over time
Rated voltage: 400V 3/N, PE, 50 Hz
Rated power: 53.5 kW
Rated current: 92.3 A
Compressor: S6J-16.2
+ Chilled water unit
Refrigerant: R404A
Weight: 5500 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
ارسال درخواست
تلفن & فکس
+49 2861 ... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۲۷ km
CTSTemperaturkammer
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۳۴ km
CTS KlimaprüfzelleCW-60/6
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۲۷ km
TIRABegehbare Klimazelle TTZ 4008 S(m)
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است