Bioer Quant Gene 9600 Fluorescent Quantitative Detection SystemBioer Quant Gene 9600
Gene 9600
Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
Bioer Quant Gene 9600
Gene 9600
وضعیت
کارکرده
موقعیت
Duxford 

اطلاعات دستگاه
قیمت و مکان
- موقعیت:
- Duxford, UK

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A20124805
- شماره مرجع:
- PR-001.SR4C
- بهروزرسانی:
- آخرین بهروزرسانی در ۱۰.۰۱.۱۴۰۵
توضیحات
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Gjdpsxhgfgofx Ac Debp
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Gjdpsxhgfgofx Ac Debp
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
تأمینکننده
توجه: به صورت رایگان ثبتنام کنید یا وارد شوید, تا به تمام اطلاعات دسترسی داشته باشید.
ثبت شده از: 2019
۷۹۷ آگهیهای آنلاین
ارسال درخواست
تلفن & فکس
+44 20 38... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
آگهی کوچک
Győr
۳٬۴۶۵ km
Instrumentation LaboratoryGEM Premier 4000
آگهی کوچک
Piskorzów
۳٬۶۱۴ km
SystecDE - 150
آگهی کوچک
Świdno
۳٬۴۲۱ km
Mercedes-Benzsprinter 318
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است