Control cabinet subrack
Areva Teleperm XS

VB به اضافه مالیات بر ارزش افزوده
‎€۶٬۵۵۰
وضعیت
جدید
موقعیت
Borken آلمان
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
Control cabinet subrack Areva Teleperm XS
more Images
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
Areva Teleperm XS
تصاویر نشان می‌دهند
نمایش نقشه

اطلاعات دستگاه

نام دستگاه:
Control cabinet subrack
تولید کننده:
Areva
مدل:
Teleperm XS
وضعیت:
نو

قیمت و مکان

VB به اضافه مالیات بر ارزش افزوده
‎€۶٬۵۵۰
موقعیت:
Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland آلمان
تماس بگیرید

جزئیات پیشنهاد

شناسه آگهی:
A16417386
شماره مرجع:
38434
به‌روزرسانی:
آخرین به‌روزرسانی در ۰۶.۰۶.۱۴۰۴

توضیحات

Areva Teleperm XS Control Cabinet

Standard Construction
For the construction of Teleperm XS systems,
SC 9422 control cabinets (2200 x 900 x 400 mm deep), IP30 protection class, are typically used.
The cabinet is equipped with cable clamps with shielding bars.
The cabinet is designed for seismic loads.
Cable entry and power supply are generally from below.
In the standard cabinet, the subracks are mounted in the middle section.
To the left and right of these are areas for mounting cabinet connection elements and transceivers.
Terminal blocks are used to connect peripheral cables.
Other connection technologies, such as Maxi-Termi-Point, are also possible.
Field cables must be shielded with twisted pairs.
Buses are implemented using conventional cables within a cabinet and fiber optic cables outside the cabinet.
Teleperm XS is suitable for systems with both surface grounding and central grounding (CEP).

Subracks
Various subrack configurations are used depending on the application.

The basic version of the subrack has a continuous backplane bus and offers 21 slots.
If large signal volumes need to be recorded, expansion subracks can be connected.

Variants are also supported:
- Split racks with two smaller, independent computers
(10 slots each, each with its own fans and power supply)
- Mixed configurations such as the compact combination of a computer with the associated signal conditioning modules

SC 9422 Control Cabinet
with cross bracing
Double doors
Cabinet indicator light
Height × Width × Depth: 2200 × 900 × 400 mm
Protection class: IP30
Power consumption: typical 550 W, max 1280 W
Weight: 300 kg

Gedpfxetzaxme Adhskf
Other items in other sizes – new and used – can be found in our shop!
International shipping costs upon request!

تأمین‌کننده

تماس بگیرید

ارسال درخواست

زمینus 
آلمان
اتریش
سوئیس
ایالات متحده آمریکا
بریتانیا
فرانسه
بلژیک
اسپانیا
مکزیک
ایتالیا
هلند
لهستان
فدراسیون روسیه
بلاروس (جمهوری بلاروس)
اوکراین
استونی
ترکیه
نیوزیلند
ایرلند
جمهوری چک
دانمارک
فنلاند
سوئد
نروژ
لوکزامبورگ
یونان
لیتوانی
لتونی
ایسلند
پرتغال
برزیل
ونزوئلا
آرژانتین
مجارستان
اسلواکی
رومانیہ
مولداوی
اسلوونی
صربستان
مونته‌نگرو
آلبانی
کرواسی
بلغارستان
مقدونیه شمالی
بوسنی و هرزگوین
اسرائیل
مصر
مراکش
هند
اندونزی
کره جنوبی
ژاپن
تایلند
مالزی
ویتنام
China
تایوان
ایران
بنگلادش
توجه: درخواست شما به همه فروشندگان دسته‌بندی ماشین‌آلات ارسال خواهد شد. با این کار می‌توانید تعداد زیادی پیشنهاد دریافت کنید.
درخواست ارسال نشد. لطفاً بعداً دوباره تلاش کنید.

تلفن & فکس

+49 2862 ... آگهی‌ها