Fuel vapor loading test benchSIGA
GS-517-400
Fuel vapor loading test bench
SIGA
GS-517-400
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۳۱٬۰۰۰
وضعیت
کارکرده
موقعیت
Borken 

تصاویر نشان میدهند
نمایش نقشه
اطلاعات دستگاه
قیمت و مکان
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۳۱٬۰۰۰
- موقعیت:
- Einsteinstraße 8a, 46325 Borken, Deutschland

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A17498838
- شماره مرجع:
- 24324
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۵.۰۸.۱۴۰۳
توضیحات
Siga
Type: GS-517-400
External dimensions LxDxH 4960 x 2500 x 2400 mm.
Complete system is calibrated according to DAKKS and
and therefore approved for approval-relevant tests
Butane loading speed
- infinitely variable from 5 g/h to 77 g/h
Loading speed fuel
- infinitely variable from 5 g/h to 100 g/h
Fuel temperature control
- infinitely variable from 20°C to 50°C
Fuel quantity selectable
- from 0 l to 8 l
Selectable breakthrough criterion
- from 1g to 10g
Purge air flow temperature
- Infinitely variable from 25°C to 30°C
Precision scales for test piece and reference AKF
- Measuring range up to 6 kg, 0.1 8 resolution
Purging vacuum
- Infinitely variable from 0 hPa to 30 hPa
Rinsing air flow
- infinitely variable from 1 l /min to 60 l/min
Humidity purge air flow
- infinitely variable from 10% rH to 85% rH
Number of cycles from 1 to 999 (load/purge)
Condition: gebraucht / used
Knedeu Aa A Aepfx Afpjf
Sale ex location!
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Type: GS-517-400
External dimensions LxDxH 4960 x 2500 x 2400 mm.
Complete system is calibrated according to DAKKS and
and therefore approved for approval-relevant tests
Butane loading speed
- infinitely variable from 5 g/h to 77 g/h
Loading speed fuel
- infinitely variable from 5 g/h to 100 g/h
Fuel temperature control
- infinitely variable from 20°C to 50°C
Fuel quantity selectable
- from 0 l to 8 l
Selectable breakthrough criterion
- from 1g to 10g
Purge air flow temperature
- Infinitely variable from 25°C to 30°C
Precision scales for test piece and reference AKF
- Measuring range up to 6 kg, 0.1 8 resolution
Purging vacuum
- Infinitely variable from 0 hPa to 30 hPa
Rinsing air flow
- infinitely variable from 1 l /min to 60 l/min
Humidity purge air flow
- infinitely variable from 10% rH to 85% rH
Number of cycles from 1 to 999 (load/purge)
Condition: gebraucht / used
Knedeu Aa A Aepfx Afpjf
Sale ex location!
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.