Magellan Instruments Tandem Pro Gas AnalyserMagellan Instruments
Tandem Pro
Magellan Instruments Tandem Pro Gas Analyser
Magellan Instruments
Tandem Pro
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۲٬۰۹۸
وضعیت
کارکرده
موقعیت
Duxford 

اطلاعات پایه
- نام دستگاه:
- Magellan Instruments Tandem Pro Gas Analyser
- تولید کننده:
- Magellan Instruments
- مدل:
- Tandem Pro
- وضعیت:
- کارکرده
قیمت و مکان
قیمت ثابت به اضافه مالیات بر ارزش افزوده
€۲٬۰۹۸
- موقعیت:
- Duxford, UK

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A20568500
- شماره مرجع:
- 412997
- بهروزرسانی:
- آخرین بهروزرسانی در ۲۸.۰۸.۱۴۰۴
توضیحات
This listing is for a Magellan Instruments Tandem Pro Gas Analyser.
The unit is in full working condition and is ready for immediate release.
The Magellan Instruments Tandem Pro Gas Analyzer is a self-contained O2 & CO2 gas analyzer. The PRO system comes with an internal gas pump and programmable display. It includes calibration functions, error reporting and dual 4-20mA outputs. An RS232 output is included for integration into control systems.
Benefits:
Greater understanding of your cells and processes
Physiological state measurement on-line
Scale-up and scale-down predictions
Batch variation studies: feature analysis
Metabolic flux analysis and mass-balance calculations
Accurate fed-batch control
Batch variation studies: anomaly analysis
Metabolic activity based feeding
Dedicated, continuous, standard signals for all your reactors
On-line information, allows real-time calculation of RQ, CER, OUR, growth rate, KLa, etc.
0-10V and 4-20mA, with RS232 on PRO & Multiplex
Integrates to any reactor size (250ml – 100m3)
Specifications:
Feature CO2 O2
Measurement Principle: Infrared Absorption Electrochemical
Range: 0-5%, 0-10%, 0-20% 0-30%, 0-50%, 0-100%
Bdodpfxsxx Aqys Abnji
Resolution: 0.01% 0.01%
Accuracy: ±2% of full scale ±2% of full scale
Drift:
The unit is in full working condition and is ready for immediate release.
The Magellan Instruments Tandem Pro Gas Analyzer is a self-contained O2 & CO2 gas analyzer. The PRO system comes with an internal gas pump and programmable display. It includes calibration functions, error reporting and dual 4-20mA outputs. An RS232 output is included for integration into control systems.
Benefits:
Greater understanding of your cells and processes
Physiological state measurement on-line
Scale-up and scale-down predictions
Batch variation studies: feature analysis
Metabolic flux analysis and mass-balance calculations
Accurate fed-batch control
Batch variation studies: anomaly analysis
Metabolic activity based feeding
Dedicated, continuous, standard signals for all your reactors
On-line information, allows real-time calculation of RQ, CER, OUR, growth rate, KLa, etc.
0-10V and 4-20mA, with RS232 on PRO & Multiplex
Integrates to any reactor size (250ml – 100m3)
Specifications:
Feature CO2 O2
Measurement Principle: Infrared Absorption Electrochemical
Range: 0-5%, 0-10%, 0-20% 0-30%, 0-50%, 0-100%
Bdodpfxsxx Aqys Abnji
Resolution: 0.01% 0.01%
Accuracy: ±2% of full scale ±2% of full scale
Drift:
تأمینکننده
توجه: به صورت رایگان ثبتنام کنید یا وارد شوید, تا به تمام اطلاعات دسترسی داشته باشید.
ثبت شده از: 2019
۷۷۲ آگهیهای آنلاین
ارسال درخواست
تلفن & فکس
+44 20 38... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
موفق
پیام شما ارسال شد.
آگهی کوچک
آلمان
۴٬۲۸۵ km
MITUTOYOSURFTEST SV-500
موفق
پیام شما ارسال شد.
آگهی کوچک
Krefeld
۴٬۳۳۸ km
WOLPERTDIA Testor 2Rc
موفق
پیام شما ارسال شد.
آگهی کوچک
Misterton
۴٬۸۶۸ km
InoxpaSE35
موفق
پیام شما ارسال شد.
آگهی کوچک
Würzburg
۴٬۰۶۷ km
UnbekanntArbeitstisch Packtisch Werkbank
موفق
پیام شما ارسال شد.
آگهی کوچک
Hessisch Lichtenau
۴٬۱۱۹ km
BEHAUNITEST Power Analyzer 93555
موفق
پیام شما ارسال شد.
آگهی کوچک
Wiefelstede
۴٬۲۸۰ km
Hahn+KolbSchlaghärteprüfer
موفق
پیام شما ارسال شد.
آگهی کوچک
Tönisvorst
۴٬۳۴۴ km
Bauart Professor BaumannNr.523
موفق
پیام شما ارسال شد.
آگهی کوچک
Lengerich
۴٬۲۷۰ km
TAD ElektronikGD05-O2
موفق
پیام شما ارسال شد.
آگهی کوچک
Wiefelstede
۴٬۲۸۰ km
LorenzK-12 EF 35-20-501
موفق
پیام شما ارسال شد.
آگهی کوچک
Tönisvorst
۴٬۳۴۴ km
MÜLLER INNSBRUCKWinkelmessuhr
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است


























































































