Halo Labs Horizon Particle AnalyzerHalo
Horizon
Halo Labs Horizon Particle Analyzer
Halo
Horizon
وضعیت
کارکرده
موقعیت
Duxford 

اطلاعات پایه
قیمت و مکان
- موقعیت:
- Duxford, UK

تماس بگیرید
جزئیات پیشنهاد
- شناسه آگهی:
- A20124680
- شماره مرجع:
- 55672.SR8C
- بهروزرسانی:
- آخرین بهروزرسانی در ۱۰.۰۷.۱۴۰۴
توضیحات
This listing is for a Halo Labs Horizon Particle Analyzer
The unit is in full working condition and is ready for immediate release
(No PC/Monitor)
The Horizon system from Halo Labs integrates Backgrounded Membrane Imaging (BMI) technology to accurately measure and characterize subvisible particles in a high-throughput, low-volume format. Originating from membrane microscopy, a USP lot release method, BMI images particles on a membrane surface. This fully automated, fluidics-free Horizon system employs disposable membrane plates and automated image processing for quick, reliable particle counts and sizing. Capable of characterizing particles in up to 96 samples per run using only 25 µL per sample, BMI is unaffected by solution refractive index, ensuring accurate measurement of translucent protein aggregates.
Sophisticated image processing techniques are used to analyze and acquire particle data, beginning with a background image of the membrane. After filtering samples by vacuum and capturing particles, the membrane is re-imaged with sample particles on its surface. The sample image is meticulously aligned with the background and processed pixel by pixel to remove background texture, achieving high contrast for the particles. This imaging approach yields high reproducibility and minimizes interference from membrane texture or imperfections.
Key Features:
Backgrounded Membrane Imaging (BMI) technology for precise particle measurement.
High-throughput: Capable of analyzing up to 96 samples in a single run.
Low sample volume: Requires only 25 µL per sample.
Guedpexhgaksfx Aqpoh
Fully automated, fluidics-free system for seamless operation.
Accurate measurement of translucent protein aggregates, unaffected by solution refractive index.
Sophisticated image processing for high reproducibility and minimal interference.
The unit is in full working condition and is ready for immediate release
(No PC/Monitor)
The Horizon system from Halo Labs integrates Backgrounded Membrane Imaging (BMI) technology to accurately measure and characterize subvisible particles in a high-throughput, low-volume format. Originating from membrane microscopy, a USP lot release method, BMI images particles on a membrane surface. This fully automated, fluidics-free Horizon system employs disposable membrane plates and automated image processing for quick, reliable particle counts and sizing. Capable of characterizing particles in up to 96 samples per run using only 25 µL per sample, BMI is unaffected by solution refractive index, ensuring accurate measurement of translucent protein aggregates.
Sophisticated image processing techniques are used to analyze and acquire particle data, beginning with a background image of the membrane. After filtering samples by vacuum and capturing particles, the membrane is re-imaged with sample particles on its surface. The sample image is meticulously aligned with the background and processed pixel by pixel to remove background texture, achieving high contrast for the particles. This imaging approach yields high reproducibility and minimizes interference from membrane texture or imperfections.
Key Features:
Backgrounded Membrane Imaging (BMI) technology for precise particle measurement.
High-throughput: Capable of analyzing up to 96 samples in a single run.
Low sample volume: Requires only 25 µL per sample.
Guedpexhgaksfx Aqpoh
Fully automated, fluidics-free system for seamless operation.
Accurate measurement of translucent protein aggregates, unaffected by solution refractive index.
Sophisticated image processing for high reproducibility and minimal interference.
تأمینکننده
توجه: به صورت رایگان ثبتنام کنید یا وارد شوید, تا به تمام اطلاعات دسترسی داشته باشید.
ثبت شده از: 2019
۷۷۲ آگهیهای آنلاین
ارسال درخواست
تلفن & فکس
+44 20 38... آگهیها
این آگهیها ممکن است برای شما نیز جالب باشند.
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۳۴ km
پمپ های خلاء، خلاء آزمايشگاهي بالا
LeyboldTrivac D 25 B /BCS
LeyboldTrivac D 25 B /BCS
موفق
پیام شما ارسال شد.
آگهی کوچک
Dievogala
۳٬۴۲۹ km
Clextralsemi-moist pet treat line ExtruderBC-45
موفق
پیام شما ارسال شد.
آگهی کوچک
Krotoszyn
۳٬۶۲۶ km
Karl SchnellF150
موفق
پیام شما ارسال شد.
آگهی کوچک
Suffolk
۴٬۷۵۰ km
FarleygreeneSieve
موفق
پیام شما ارسال شد.
آگهی کوچک
Duxford
۴٬۷۸۷ km
Particle Measuring SystemsLASAIR lll 310c
موفق
پیام شما ارسال شد.
آگهی کوچک
Misterton
۴٬۸۶۸ km
Gough EngineeringGV1
موفق
پیام شما ارسال شد.
آگهی کوچک
Wiefelstede
۴٬۲۷۹ km
منبع تغذیه آزمایشگاهی
MANSONEP-613
MANSONEP-613
موفق
پیام شما ارسال شد.
آگهی کوچک
Borken
۴٬۳۳۴ km
IKALR 2000 V
آگهی شما با موفقیت حذف شد
یک خطا رخ داده است