Applied Biosystems ViiA7
Here we offer an Applied Biosystems ViiA7.
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds of reaching the target temperature
Iisdpfx Ajzd Ud Njbxec
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100 μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target amounts in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support are provided by Life Technologies)
Remote notification: Notifies the user by email when the run starts, stops, or is aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used
Scope of supply: (See image)
(Changes and errors in technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
آگهی به صورت خودکار ترجمه شده است. احتمال بروز اشتباه در ترجمه وجود دارد.
Here we offer an Applied Biosystems ViiA7.
Specifications:
Block change from the front of the instrument in less than 1 minute; no secondary tools required
Supported applications: Standard curve, comparative CT, genotyping, presence/absence, HRM, melting curve
Temperature uniformity: ±0.5 °C, within 30 seconds of reaching the target temperature
Iisdpfx Ajzd Ud Njbxec
Run time: ~35 min for 96/384-well blocks with Applied Biosystems® Fast Master Mix
Supported blocks and volumes: 96-well standard (10–100 μl reactions)
96-well Fast (10–30 μl reactions) • 384-well (5–20 μl reactions)
TaqMan® Array Micro Fluidic Cards (~1 μl reactions)
Detectable sensitivity: up to 1 copy • Excitation/detection wavelengths: 6 excitation (450–670 nm)
6 emission (500–720 nm) • Dynamic range: Up to 9 logs linear dynamic range
Resolution: Detects only 1.5-fold changes in target amounts in a singleplex reaction
21 CFR p11 Enablement: Security, audit, and e-signature functions for instrument data
Automation: Includes plate loading arm with barcode (distribution, service, and support are provided by Life Technologies)
Remote notification: Notifies the user by email when the run starts, stops, or is aborted
Data export format: Fully configurable by the user
Description:
Applied Biosystems Real-time PCR ViiA7.
Ideal for performing real-time PCR with medium to high throughput.
Interchangeable blocks for 96-well, Fast 96-well, and 384-well plates
as well as TaqMan Array Cards. Fast block change.
Touchscreen interface.
2x Ethernet connection. 2x USB connection.
1x RS 232 connection. 2x connection on the display.
Weight: 67 kg
Type: Applied Biosystems ViiA7
Condition: used
Scope of supply: (See image)